SYD-0956B Automatic Houillon Viscosity Tester
Summary SYD-0956B automatic folded tube kinematic viscosity tester is designed and manufactured according to the standard SH / T0956-2017 Determination of Kinematic Viscosity of Transparent and Opaque Liquids by Folded Tube Automatic Viscometer&qu
SYD-0956B Automatic Houillon Viscosity Tester
Summary
SYD-0956B automatic folded tube kinematic viscosity tester is designed and manufactured according to the standard SH / T0956-2017 "Determination of Kinematic Viscosity of Transparent and Opaque Liquids by Folded Tube Automatic Viscometer" and ASTM D7279 "Standard Test method For Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer", It is suitable for the determination of kinematic viscosity of transparent and opaque liquids, including base oil, blended lubricating oil, biodiesel, Biodiesel Blended fuel, residual fuel oil, marine oil,etc.
I. Main technical features
1. Full automatic control, one key start detection, the test process includes measurement, cleaning, drying, test results calculation and data storage. It will stop automatically after the test.
2. The measuring speed is fast, the fastest measuring time is no more than 30s, and the average measuring time is less than 3 minutes.
3. The instrument has dual solvent automatic cleaning function, which can quickly clean the folded tube viscometer, and the consumption of cleaning agent in one cleaning process is not more than 15ml.
4. The instrument adopts high-precision sensors, and the temperature of the bathtub is uniform and stable, with a temperature control accuracy of 0.01 ℃.
5. It is convenient and quick to replace the folded tube viscometer. The viscometer can be replaced without draining the bath liquid. The replacement can be completed within 2 minutes.
6. The constant temperature bath of the instrument adopts high-temperature resistant borosilicate glass, which has good perspective and insulation properties
II.Main technical specifications
Power supply | AC(220±10%)V,50Hz |
Single Bathtube volume | 1.5L |
Measurement range | 3~3000mm2/s |
Sample qty | (0.3~1)mL |
Time control accuracy | 0.01℃ |
Timing accuracy | 0.01s |
Test time | within 3 minutes (the whole process of measurement, cleaning and drying is within 10 minutes) |
Temperature control range | room temperature ~ 150℃ |
Repeatability | ≤0.68% |
Detection unit | Double folded tube viscometer |
Operation interface | 15 inch IPC |
Total power consumption | ≤1400W |
Working temperature | (10~30)℃ |
Net weight | 38kg |